Pharmaceutical and biotech: process air, nitrogen and CO₂
Follow process air, nitrogen and CO₂ through a pharmaceutical plant and lab. Tap each point to see what is measured and which YORK analyzer fits.
Pharmaceutical and biotech plants use compressed air and nitrogen that touch the product, nitrogen to keep solvent reactors safe, and CO₂ to run cell culture. Each has a quality limit that is written into the plant's qualification documents and checked routinely.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
- Process air. Oil-free compressors and dryers supply air for filling, coating and fermentation, qualified against ISO 8573-1 classes.
- Nitrogen supply. Liquid nitrogen is vaporised, or a generator supplies gaseous nitrogen, for blanketing and inert transfers.
- Reactor blanketing. Nitrogen keeps oxygen in solvent reactor headspaces below the limiting oxygen concentration.
- Freeze drying. Dry nitrogen breaks the vacuum and backfills vials before stoppering.
- Cell culture. CO₂ incubators and bioreactor gas mixes hold the pH of the culture medium.
Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | YORK instrument |
|---|---|---|---|---|
| 1 | Compressed air after the dryer | Pressure dew point | Product-contact air is commonly specified as ISO 8573-1 class 2 for water (−40 °C pressure dew point) or drier | DPT830, DPT810 |
| 2 | Point of use (qualification test) | Pressure dew point at the point of use | Same limit as the system specification | DPT-600 Plus |
| 3 | Freeze dryer backfill gas | Moisture in the nitrogen used to break vacuum and stopper vials | Very dry; set by the product's residual-moisture requirement | DPT830 |
| 4 | Solvent reactor headspace (nitrogen blanket) | Oxygen in the headspace | Kept below the limiting oxygen concentration of the solvent, with a safety margin set by the plant | PGA530, POA300 |
| 5 | Nitrogen supply after the vaporizer | Residual oxygen | Set by the nitrogen specification | PGA500 |
| 6 | CO₂ incubators and bioreactor gas | CO₂ concentration | Cell-culture incubators are commonly set to about 5% CO₂ | PGA620, PGA520 |
Questions we are asked
What dew point does GMP compressed air need?
The plant's specification decides. Product-contact air is commonly specified as ISO 8573-1 class 2 for water, a −40 °C pressure dew point, or drier.
Can YORK analyzers be installed near solvent reactors?
Areas around solvent reactors are usually hazardous zones. The usual approach is to draw the sample to a safe area. If the analyzer must sit inside the zone, confirm the certification your site requires before ordering.
How is an incubator's CO₂ reading checked?
With an independent analyzer such as the portable PGA620, sampling from the incubator's test port.