Fruit storage and ripening: oxygen and CO₂ in CA stores and ripening rooms

Follow nitrogen and CO₂ control in a controlled-atmosphere cold store and ventilation in ripening rooms. Tap each point to see what is measured and which YORK analyzer fits.

Fruit exporters and distributors in Spain, Thailand, Vietnam and across Europe store apples and pears for months in controlled atmosphere and ripen bananas and avocados close to market. Both depend on holding oxygen and CO₂ at the right levels, room by room.

SAMPLE LINESN₂ GENERATOR(MEMBRANE)CO₂ SCRUBBERCA COLD STOREAPPLES / PEARS IN BINSRIPENING ROOMSBANANA / AVOCADOPALLETSMULTIPOINT GASANALYSIS PANELFRESH-AIR FAN1O₂ %2CO₂ %3O₂4CO₂
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

  1. Loading and pull-down. After loading, a nitrogen generator lowers the oxygen in the sealed store.
  2. Storage. Oxygen and CO₂ are held at setpoints for the variety; a scrubber removes excess CO₂.
  3. Monitoring. Sample lines from each room lead to a multipoint analysis panel.
  4. Ripening. Ripening rooms start ripening with ethylene and are ventilated to keep CO₂ low.
  5. Dispatch. Rooms are opened and ventilated before people enter.
About the values

Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.

Measurement points at a glance

#PointMeasuresTypical value / limitYORK instrument
1CA store atmosphere: oxygenOxygen in the storeKept low, typically about 1–3% for apples and pears; set per variety and seasonPGA530, POA300
2CA store atmosphere: CO₂CO₂ in the storeTypically about 1–5%, set per variety; the scrubber removes the excessPGA520
3Nitrogen generator outletResidual oxygenMembrane generators commonly deliver about 95–99.5% N₂PGA530
4Ripening room CO₂CO₂ in the roomVentilated to keep CO₂ low, often below about 1%PGA520, PGA620

Questions we are asked

Can one analyzer serve several rooms?

Yes. A multipoint panel switches sample lines from each room to one oxygen and one CO₂ analyzer in turn.

Does YORK measure ethylene?

No. YORK instruments measure oxygen, CO₂ and moisture.

Which CO₂ range suits a CA store?

The PGA520 0–5% range covers typical store and ripening-room levels.

Discuss your application