Electronics assembly: oxygen in soldering nitrogen, dry air and dry storage
Follow air and nitrogen from the compressor room to the reflow oven, the solder wave and the dry cabinet. Tap each point to see what is measured and which YORK analyzer fits.
Surface-mount and through-hole lines in Vietnam, Thailand, Singapore and across Europe run their soldering ovens in nitrogen, usually from an on-site PSA generator. The numbers that matter are the oxygen level in the oven, the purity the generator delivers and the dryness of the compressed air that runs the line.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
- Compressed air. An oil-free or filtered compressor and a dryer supply clean dry air to pick-and-place machines and pneumatics.
- Nitrogen generation. A PSA generator separates nitrogen from the same compressed air and fills a buffer tank.
- Reflow soldering. Nitrogen purges the reflow oven so the solder melts and wets with little oxidation.
- Wave and selective soldering. Nitrogen reduces dross on the solder bath and improves through-hole joints.
- Dry storage. Moisture-sensitive components wait in dry cabinets until they are placed.
Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | YORK instrument |
|---|---|---|---|---|
| 1 | CDA dryer outlet | Pressure dew point | Often −40 °C pressure dew point (ISO 8573-1 class 2), set by the plant | DPT810, DPT830 |
| 2 | Nitrogen generator outlet | Residual oxygen (nitrogen purity) | Soldering generators are commonly set between about 99.9% and 99.999% N₂, i.e. about 1,000 to 10 ppm O₂ | PGA500, PGA530 |
| 3 | Reflow oven atmosphere | Residual oxygen in the oven | Commonly about 100–1,000 ppm, set by the solder paste and the product | PGA500, POA200 |
| 4 | Wave or selective soldering | Residual oxygen in the solder tunnel or nozzle area | Set by the machine and the process | POA200, PGA500 |
| 5 | Dry cabinet for moisture-sensitive devices | Humidity, checked as dew point | Cabinets commonly run at 5–10% RH at room temperature: about −16 °C to −8 °C frost point at 25 °C | DPT-600 Plus |
Questions we are asked
Which oxygen analyzer suits a reflow oven?
The PGA500 in-line analyzer covers 0.01 ppm to 25% O₂, which spans typical oven setpoints and an air-ingress alarm. The portable POA200 does the same for audits.
Can one analyzer serve several ovens?
A portable analyzer can check several ovens on a round. For continuous control, each oven usually has its own in-line analyzer or a shared sample system with switching.
Does the nitrogen generator need its own analyzer?
It helps. A rising oxygen level at the generator shows a problem before it reaches the ovens and lets you tune purity against running cost.