Dew point calibration
Calibrate dew point analyzers and transmitters in-house, against a chilled mirror reference, instead of shipping them away.
Who needs it
- Instrument service laboratories that calibrate customers' moisture analyzers.
- Plants with many dew point points — gas processing, air separation, compressed air — that want short calibration turnaround.
- Metrology institutes and quality departments that need a traceable reference for sub-zero dew points.
- Distributors that want to offer calibration alongside instrument sales.
In many markets few commercial laboratories calibrate below 0 °C dew point, so analyzers are sent abroad and are out of service for weeks. An in-house system removes that wait.
YKDC220 low-humidity calibration system
A 19-inch rack system with a separately installed compressor. It combines a dry gas generator, a low-humidity generator and a chilled mirror reference hygrometer with the connecting gas lines.
How the system works
The DC1000 makes very dry air; the DC2000 mixes dry and wet gas to the set dew point; the reference hygrometer and the instruments under test see the same gas.
On a phone, swipe the diagram sideways.
| Component | Role | Key data |
|---|---|---|
| YK-2×750-55 | Compressed air supply | Fully enclosed, oil-free compressor with pre-dryer and sound-muffling cabinet |
| DC1000 | Dry gas generator | Pressure swing adsorption; up to 10 NL/min of dry air at 1 ppmV or less (−75 °C dew point); 1/4" stainless steel compression fittings |
| DC2000 | Low-humidity generator | Flow-divided mixing with four electronic mass flow controllers; fluctuation less than ±0.2 °C frost point; multiple user-configurable calibration points; three outlets (one reference, two calibration) |
| DM9700 / DM9800 / DM9900 | Reference hygrometer | Chilled mirror; DM9900 to −90 °C frost point, better than ±0.2 °C near −90 °C; calibration certificate available (chargeable) |
Typical procedure
- Purge the lines with dry gas from the DC1000 until the reference reads stable.
- Set the first calibration point on the DC2000; wait for the reference and the instruments under test to stabilise.
- Record reference and instrument readings; repeat at each user-configured point.
- Adjust or certify each instrument against the reference readings.
The system is designed to the equipment set required by the Chinese verification regulation JJG 499-2004 for precision dew point meters. Your quality system defines the points and acceptance limits.
- The YKDC220 is configured and quoted per project, including the choice of reference hygrometer.
- The calibrated range depends on the reference chosen: DM9700 to −70 °C, DM9800 to −80 °C, DM9900 to −90 °C frost point.