Brewery CO₂ recovery: from fermenter to filling hall
Follow fermentation CO₂ through scrubbing, compression, drying and liquefaction back to carbonation. Tap each point to see what is measured and which YORK analyzer fits.
Breweries in Denmark, Vietnam, Thailand and elsewhere recover the CO₂ from fermentation, purify it and use it again for carbonation, instead of buying it in. Recovery pays back only if the gas is collected at the right time and dried and purified to beverage grade.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
- Fermentation. Yeast produces CO₂; early gas still contains air.
- Scrubbing. A foam trap and water scrubber remove foam and water-soluble impurities.
- Compression and purification. The gas is compressed, passed through activated carbon and dried.
- Liquefaction. Dry CO₂ is liquefied and stored.
- Reuse. A vaporizer supplies CO₂ to carbonation, filling and purging.
Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | YORK instrument |
|---|---|---|---|---|
| 1 | Fermenter off-gas | CO₂ concentration | Recovery starts once the off-gas is rich enough in CO₂; the threshold is set by the recovery plant supplier | PGA520 |
| 2 | After the dryer, before the liquefier | Moisture | Very dry to avoid ice in the liquefier | DPT830 |
| 3 | CO₂ to carbonation | Moisture in the CO₂ | Beverage-grade specifications commonly limit water to about 20 ppm by volume (about −55 °C frost point at 1 atm) | DPT-600 Plus |
| 4 | Recovered CO₂ purity | Trace oxygen and other impurities | Beverage-grade specifications set oxygen at the ppm level | ; integrated system: trace oxygen analyzer for CO₂ service |
| 5 | Filling hall and cellar air | CO₂ in room air (safety) | Workplace exposure limit 5,000 ppm (8-hour average) in the UK and many EU countries | PGA520 |
Questions we are asked
Can YORK verify beverage-grade CO₂ purity?
YORK instruments check moisture. Trace oxygen and other impurities at ppm level need dedicated analyzers, available as an integrated system.
Why not measure oxygen in CO₂ with an electrochemical cell?
Electrochemical cells are not used in a CO₂ background. Percent-level oxygen in CO₂ needs a paramagnetic analyzer; ppm levels need a trace analyzer.
What CO₂ level is unsafe in a cellar?
The UK and many EU countries set a workplace exposure limit of 5,000 ppm averaged over 8 hours. Alarm levels follow your safety assessment.