Biogas and biomethane: oxygen, CO₂ and dew point from digester to grid

Follow biogas from the digester through drying and upgrading to the gas grid, with CO₂ recovery and a CHP engine. Tap each point to see what is measured and which YORK analyzer fits.

Europe's biomethane plants, from Denmark and France to the UK and Sweden, inject upgraded biogas into the gas grid. Grid operators set limits for water dew point, CO₂ and oxygen, and the plant has to prove it meets them continuously.

TO GAS GRIDAIR DOSING (BIO-DESULF.)OFF-GASBIOMETHANEDIGESTERDESULF.CHILLER /DRYERCOMPRESSORUPGRADING(MEMBRANE / PSA)GRID INJECTIONSTATIONCO₂ RECOVERYLIQUID CO₂CHP ENGINE1O₂·CO₂2H₂O3CO₂·O₂4H₂O5H₂O6H₂O
YORK instrumentIntegrated system (supplied through YORK)

Tap a numbered point. Swipe the diagram sideways on a phone.

Request a quote for this point →
Auto tour
Project list 0 →

How the process works

  1. Digestion. Organic feedstock produces raw biogas, roughly 50–65% methane and the rest mainly CO₂.
  2. Pre-treatment. Hydrogen sulphide is removed, often with air dosing for biological desulphurisation, and the gas is chilled or dried.
  3. Upgrading. Membranes, PSA, water scrubbing or amine units separate CO₂ from methane.
  4. Grid injection. The injection station checks quality, measures energy content, odorises and compresses the gas.
  5. By-products. Off-gas CO₂ can be recovered and liquefied; raw biogas may also fuel a CHP engine.
About the values

Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.

Measurement points at a glance

#PointMeasuresTypical value / limitYORK instrument
1Raw biogas after the digesterOxygen and CO₂ (methane is measured separately)Typically about 35–50% CO₂; oxygen from air dosing kept low, usually below about 1%POA3500, PGA520
2After the chiller or dryerDew pointSet by the upgrading supplier; chillers typically dry to a few °C dew point, adsorption dryers go lowerDPT830
3Biomethane at the upgrading outletResidual CO₂ and oxygenSet by the national grid code; residual CO₂ is often limited to a few percentPGA520, POA3500
4Grid injection stationWater dew point (plus calorific value and composition)Water dew point at a reference pressure, set by the grid operatorDPT830; integrated system: process gas chromatograph for calorific value and composition
5CO₂ recovery feedMoisture before liquefactionMust be very dry to avoid ice in the liquefier; beverage-grade CO₂ is commonly limited to about 20 ppm waterDPT830
6CHP engine fuelDew point after the chillerSet by the engine manufacturerDPT810

Questions we are asked

Why use a paramagnetic oxygen analyzer for biogas?

Raw biogas contains 35–50% CO₂. Electrochemical oxygen cells are not used in a CO₂ background, so a paramagnetic analyzer such as the POA3500 is used.

Can YORK measure methane and H₂S?

Not with YORK instruments. Methane, calorific value and H₂S are measured by gas chromatographs or dedicated analyzers, which YORK can supply as part of an integrated system.

Do the analyzers need hazardous-area certification?

Biogas areas are usually classified zones. Install the analyzers in a safe area with sample lines, or confirm the certification your site requires before ordering.

Discuss your application