Industries
Biogas and biomethane: oxygen, CO₂ and dew point from digester to grid
Follow biogas from the digester through drying and upgrading to the gas grid, with CO₂ recovery and a CHP engine. Tap each point to see what is measured and which YORK analyzer fits.
Europe's biomethane plants, from Denmark and France to the UK and Sweden, inject upgraded biogas into the gas grid. Grid operators set limits for water dew point, CO₂ and oxygen, and the plant has to prove it meets them continuously.
Tap a numbered point. Swipe the diagram sideways on a phone.
How the process works
- Digestion. Organic feedstock produces raw biogas, roughly 50–65% methane and the rest mainly CO₂.
- Pre-treatment. Hydrogen sulphide is removed, often with air dosing for biological desulphurisation, and the gas is chilled or dried.
- Upgrading. Membranes, PSA, water scrubbing or amine units separate CO₂ from methane.
- Grid injection. The injection station checks quality, measures energy content, odorises and compresses the gas.
- By-products. Off-gas CO₂ can be recovered and liquefied; raw biogas may also fuel a CHP engine.
Values are typical figures from published specifications and industry practice. Your plant, licensor or grid specification always governs.
Measurement points at a glance
| # | Point | Measures | Typical value / limit | YORK instrument |
|---|---|---|---|---|
| 1 | Raw biogas after the digester | Oxygen and CO₂ (methane is measured separately) | Typically about 35–50% CO₂; oxygen from air dosing kept low, usually below about 1% | POA3500, PGA520 |
| 2 | After the chiller or dryer | Dew point | Set by the upgrading supplier; chillers typically dry to a few °C dew point, adsorption dryers go lower | DPT830 |
| 3 | Biomethane at the upgrading outlet | Residual CO₂ and oxygen | Set by the national grid code; residual CO₂ is often limited to a few percent | PGA520, POA3500 |
| 4 | Grid injection station | Water dew point (plus calorific value and composition) | Water dew point at a reference pressure, set by the grid operator | DPT830; integrated system: process gas chromatograph for calorific value and composition |
| 5 | CO₂ recovery feed | Moisture before liquefaction | Must be very dry to avoid ice in the liquefier; beverage-grade CO₂ is commonly limited to about 20 ppm water | DPT830 |
| 6 | CHP engine fuel | Dew point after the chiller | Set by the engine manufacturer | DPT810 |
Questions we are asked
Why use a paramagnetic oxygen analyzer for biogas?
Raw biogas contains 35–50% CO₂. Electrochemical oxygen cells are not used in a CO₂ background, so a paramagnetic analyzer such as the POA3500 is used.
Can YORK measure methane and H₂S?
Not with YORK instruments. Methane, calorific value and H₂S are measured by gas chromatographs or dedicated analyzers, which YORK can supply as part of an integrated system.
Do the analyzers need hazardous-area certification?
Biogas areas are usually classified zones. Install the analyzers in a safe area with sample lines, or confirm the certification your site requires before ordering.